ASB02505SHA-AY6B Spec Datasheet by Delta Electronics

A ISELTlI SPECIFICATION FOR APPROVAL
SPECIFICATION FOR APPROVAL
Customer.
Description.
Delta Model No.
Sample Issue No.
Sample Issue Date.
PLEASE SEND ONE COPY OF THIS SPECIFICATION
BACK AFTER YOU SIGNED APPROVAL FOR PRODUC-
TION PRE-ARRANGEMENT.
APPROVED BY :
DATE:
Delta Electronics, Inc.
HeTianXia High-Tech Industrial Park.
Shi Jie Town, Dong Guan City.
Guangdong Province, China. P. R. C.
TEL : 86-769-86329008
FAX : 86-769-86631589
Customer Part No. REV.
REV.
DPC
DC FAN
ASB02505SHA-AY6B
JUN-23-2016
00
Delta Electronics, Inc. HeTiunXia High-Tech IndusLI'iaI Park. TEL : 86-769-86329008 Shi .Iie Town, Dong Gnan City. FAX : 86776976663689 Guangdong Province, China. P. R. C. S'I‘ATEVIENT OF DEVIAI‘IOV ¥¥******IXXXX¥******X xxxxx *Mww V" IV 0N E DESCRIPTION :
Delta Electronics, Inc. HoTianXia High—T0011 Industrial Park. TEL : [56-769-86329008 Shi ,Iic Town, Dong Guan Cityi FAX : 86-769-86631589 Guangdong Province, China P. R. C. SPECIFICATION FOR APPROVAL ’(‘HPDUMWVUNDHA4’WW4VDUM‘4944WW4IV Cusiomcr: DPC De :nptmn: L SCOPE: THIS SPECIFICATION DEFINES THE ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE DC IIRIISHLESS AXIAL FLOW FAN. 24 CHARACTERS: i RATED SPEED MAX. AIR FLOW I I I (AT ZERO STATIC PRESSURE) MAX. AIR PRESSURE E) ) mmHgo (AT ZERO AIRFLOW) 1 ) inchHg 0 (continund) page: 1
PART NO: DELTA MODEL: ASBOZSOSSHA—AYESB INSULATION STRENGTH 10 MEG OHM MIN. AT 500 VDC (BETWEEN FRAME AND (+> TERMINAL) DIELECTRIC STRENGTH 5 mA MAX AT 500 VAC 50/60 Hz ONE MINUTE, (BETWEEN FRAME AND (+) TERMINAL) LIFE EXPECTANCE (LIO) 20,000 HOURS CONTINUOUS OPERATION (AT LABEL VOLTAGE) AT "IO “O WITH 15 ~ 65 ZRH. ROTATION CLOCKWISE VIEW FROM NAME PLATE SIDE NOTES: 1, [\3 ALL READINGS ARE MEASURED AFTER STADLY WARMING UI’ THROUGH 10 MINUTES, STANDARD AIR PROPERTY IS AIR AT (Td) 25°C TEMPERATURE, (RH) 65% RELATIVE HUMIDITY, AND (Pb) 760 1ang BAROMETRIC PRESSURE THE VALUES WRITTEN IN PARENS , ( ) ARE LIMITED SPEC‘ ACOUSTICAL NOISE MEASURING CONDITION: DC FAN MICROPHONE , 1: AIR FLOW 1M NOISE IS MEASURED AT RATED VOLTAGE IN FREE AIR IN SEMI—ANECHOIC CHAMBER WITH II 8: K SOUND LEVEL METER WITH MICROPHONE AT A DISTANCE OF ONE METER FROM THE FAN INTAKE, A00 page: 2
PART NO: DELTA MODEL; ASBOZSOSSHA-AYGB 3. MECHANICAL: 3—1. DIMENSIONS — SEE DIMENSIONS DRAWING 3—2. FRAME PLASTIC I'L: DIV—o 3—3. IMl’ELLER — PLASTIC UL: 94V—0 3—4. BEARING SYSTEM — SLEEVE BEARING 3—5. WEIGHT 5.6 (REE) GRAMS 4. ENVIRONMENTAL: r’lil. OPERATING TEMPERATURE — 710 T0 +70 DEGREE C 4—2. STORAGE TEMPERATURE — —40 TO +75 DEGREE C 4—3. OPERATING HUMIDITY — 5 TO 90 7, RH 4—4. STORAGE HUMIDITY— 5 TO 95 7, RH 5 PROTECTION: 5—1. LOCKED ROTOR PROTECTION IMPEDANCE OF MOTOR WINDING PROTECTS MOTOR FROM FIRE IN 96 HOIIRS OF LOCKED ROTOR CONDITION AT THE RATED VOLTAGE. 5—2. POLARITY PROTECTION RE CAPABLE OF WITHSTANDING IF REVERSE CONNECTION FOR POSITIVE AND NEGATIVE LEADS. 6. RE OZONE DEPLETING SUBSTANCES: 6—1. NO CONTAINING PBBS, PBBOS, CFCS, PBBES, PBDPES AND HCFCS. , PRODUCTION LOCATION 7—1. PRODIICTS WILL BE PRODUCED IN CHINA OR THAILAND. \‘1 A00 page: 3
8. P 8: Q CURVE: > I: AIR PRESSURE 0.35 0.4 033 0,25 0,15 005 (H 0.0 m o — I I I I I I I I 0.0 0,025 0050 0.075 0100 0.125 0.150MS/MIN, O N CK?) I I I | | 1 :I: :1: E EUIO 1,0 20 3,0 4.0 5.0 CFM 7 ,\ “ AIR FLOW > TEST CONDITION: INPUT VOLTAGE 77777 OPERATION VOLTAGE TEMPERATURE 777777 ROOM TEMPERATURE HUMIDITY 7777777777 sszRH A00
PART NO: DELTA MODEL: ASBOZiOfiSHA-AYSII 9. DIMENSION DRAWING: LABEL: / A \_‘ AI Z; 0in 150.0i100 (SIQOSiOIBQ/I) I I ‘ NOTES: me:mUN(H) 1. LEAD WIRE KL 1061 —F— AWG#28 REI) WIRE ————— BLACK WIREi BLUE WIRE ----- 2. THIS PRODUCT IS ROHS COMPLIANT, A00 page: a
PART NO: DELTA MODEL: ASBOZSOBSHA—AWB 11. FREQUENCY GENERATOR (FG) SIGNAL: 1. OUTPUT CIRCUIT — OPEN COLLECTOR NIODE: In ‘7 We I MOTOR DRIVER <4 “ce="" caution:="" the="" lead="" wire="" of="" fg="" signal="" can="" not="" touch="" the="" lead="" wire="" of="" positive="" 0r="" negative.="" 2.="" spectfication:="" m="" (sat):o‘5v="" maxi="" tl;="" :5.0="" typ.(voc="" maxi)="" in="" :5ma="" max.="" rae/1c="" 1="" frequency="" generator="" wayeform:="" nu="" 0.5v="" fg="" signal="" maxi="" i="" running="" locked="" rl'nning="" fan="" running="" for="" 4="" i-‘oles="" blade="" locked="" f=""> A) TL T" TS: Ti T1=T2=T3=T4=1/4 TS R=RRE TS:60/N(SEC) *VOLTAGE LEVEL AFTER BLADE LOCKED *4 POLES page: 7 A00
Doc. No: FMBG-ES Form 001 Rev. 0001 Date: June 24, 2009
Application Notice
1. Delta will not guarantee the performance of the products if the application condition
falls outside the parameters set forth in the specification.
2. A written request should be submitted to Delta prior to approval if deviation from
this specification is required.
3. Please exercise caution when handling fans. Damage may be caused when pressure is
applied to the impeller, if the fans are handled by the lead wires, or if the fan was
hard-dropped to the production floor.
4. Except as pertains to some special designs, there is no guarantee that the products will
be free from any such safety problems or failures as caused by the introduction of
powder, droplets of water or encroachment of insect into the hub.
5. The above-mentioned conditions are representative of some unique examples and viewed
as the first point of reference prior to all other information.
6. It is very important to establish the correct polarity before connecting the fan to the
power source. Positive (+) and Negative (-). Damage may be caused to the fans if
connection is with reverse polarity, if there is no foolproof method to protect against
such error specifically mentioned in this spec.
7. Delta fans without special protection are not suitable where any corrosive fluids are
introduced to their environment.
8. Please ensure all fans are stored according to the storage temperature limits specified.
Do not store fans in a high humidity environment. We highly recommend performance
testing is conducted before shipping, if the fans have been stored over 6 months.
9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the
rotation of the impeller for the fans that do not have this function, the performance
of those fans will lead to failure.
10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause
excess resonance, vibration and subsequent noise.
11. It is important to consider safety when testing the fans. A suitable fan guard should be
fitted to the fan to guard against any potential for personal injury.
12. Except where specifically stated, all tests are carried out at room (ambient) temperature
and relative humidity conditions of 25
o
C, 65% RH. The test value is only for fan
performance itself.
13. Be certain to connect an “ 4.7µF or greater” capacitor to the fan externally when
the application calls for using multiple fans in parallel, to avoid any unstable power.